GENTAUR Belgium BVBA BE0473327336 Voortstraat 49, 1910 Kampenhout BELGIUM Tel 0032 16 58 90 45
GENTAUR U.S.A Genprice Inc 6017 Snell Ave, Ste 357, SanJose, CA 95123
Tel (408) 780-0908, Fax (408) 780-0908, sales@genprice.com

Index / Bioassays / Malachite Green Phosphate Assay Kit / Product Detail : POMG-25H Malachite Green Phosphate Assay Kit
Related keywords:

Dec
11th

#POMG-25H Malachite Green Phosphate Assay Kit

Ask technical file .

  Price : 250   EUR
284   USD
194   GBP
1051   Zloty
33494   JPY
1930   NOK
2068   SEK
283   CHF

Product name : Malachite Green Phosphate Assay Kit

Catalog number : POMG-25H

Quantity: 2500 Tests

Availability: Yes

Supplier name : Bioassays

ask pdf gentaur products Data sheet: Ask more or other datasheet now !

More Details about

Malachite Green Phosphate Assay Kits (POMG-25H)
Rapid Colorimetric Phosphate Determination at 620 nm

DESCRIPTION
The Malachite Green Phosphate Assay Kit is based on quantification of the green complex formed between Malachite Green, molybdate and free orthophosphate. The rapid color formation from the reaction can be conveniently measured on a spectrophotometer (600 - 660 nm) or on a plate reader. The non-radioactive colorimetric assay kits have been optimized to offer superior sensitivity and prolonged shelf life. The assay is simple and fast, involving a single addition step for phosphate
determination. Assays can be executed in tubes, cuvettes or multi-well plates. The assays can be conveniently performed in 96- and 384-well plates for high-throughput screening of enzyme inhibitors.

KEY FEATURES

  • Reagent very stable. Due to our innovative formulation, no precipitation ofreagent occurs. Therefore no filtration of reagent is needed prior to assays,as is often required with other commercial kits
  • High sensitivity and wide detection range: detection of as little of 1.6pmoles of phosphate and useful range between 0.02 μM and 40 μM phosphate.
  • Fast and convenient: homogeneous “mix-and-measure” assay allows quantitation of free phosphate within 20 minutes.
  • Compatible with routine laboratory and HTS formats: assays can be performed in tubes, cuvettes or microplates, on spectrophotometers and plate readers.

Robust and amenable to HTS: Z’ factors of 0.7 to 0.9 are observed in 96-well and 384-well plates. Can be readily automated on HTS liquid handling systems.

APPLICATIONS

  • Phosphatase Assays: liberation of phosphate from peptide, protein or small molecule substrate.
  • Lipase Assays: liberation of phosphate from phospholipids Nucleoside Triphosphatase Assays: liberation of phosphate from nucleoside triphosphates (ATP, GTP, TTP, CTP etc).
  • Quantitation of Phosphate in phospholipids, proteins and DNAs, etc.
  • Drug Discovery: high-throughput screen for phosphatase inhibitors.

KIT CONTENTS: 2,500 ASSAYS IN 96-WELL PLATE
Reagent A: 50 mL
Reagent B: 1 mL
Standard: 1mL 1 mM phosphate

Storage conditions. The reagents and standard are stable for one year when stored at 4°C.

Precautions: reagents are for research use only. Normal precautions for laboratory reagents should be exercised while using the reagents. Please refer to Material Safety Data Sheet for detailed information.

PROCEDURE USING 96-WELL PLATE
Reagent Preparation.
Each assay requires 20 μL Working Reagent.
Prepare enough Working Reagent by mixing 100 vol of Reagent A and 1 vol of Reagent B (e.g. 5 mL Reagent A and 50 μL Reagent B). Working Reagent is stable for at least 1 day at room temperature.

Important: The reagent must be brought to room temperature before use.
Before each assay, it is important to check that all enzyme preparations and assay buffers do not contain free phosphate. This can be conveniently done by adding 20 μL of the Working Reagent to 80 μL sample solution.
The blank OD values at 620 nm should be lower than 0.2. If the OD readings are higher than 0.2, check water phosphate level. Double distilled water usually have OD readings lower than 0.1. Lab detergents may contain high levels of phosphate. Make sure that lab wares are free from contaminating phosphate after thorough washes.

1. Preparation of phosphate standards. Prepare a Premix solution containing 40 μM phosphate by pipetting 40 μL 1 mM phosphate standard to 960 μL distilled water or enzyme reaction buffer. Number the tubes. Dilute standards as shown in the following Table. Pipette 80 μL standard in duplicate into wells of a clear-bottom 96-well plate. Add blank controls containing water or reaction buffer only.

No Premix + H2O Final Vol(μL)  PhosphateConc (μM) pmoles Phosphate in 50 μL
1    200μL + 0μL         200                  40                                                 2,000
2    160μL + 40μL      200                   32                                                 1,600
3    120μL + 80μL      200                   24                                                 1,200
4      80μL + 120μL    200                   16                                                    800
5      60μL + 140μL    200                   12                                                    600
6      40μL + 160μL    200                     8                                                     400
7      20μL + 180μL    200                     4                                                     200
8        0μL + 200μL    200                      0                                                         0

2. Transfer 80 μL test samples into separate wells of the plate.
Note: in the case of enzyme reactions, the reaction may be terminated by adding a specific inhibitor, or can be stopped directly by the addition of the Working Reagent. Dilution of reaction mixture may be necessary prior to the assay (see General Considerations). For ATPase or GTPase assays, the ATP or GTP concentration should be lower than 0.25 mM. If the reaction mixture contains > 0.25mM ATP or GTP, dilute samples in distilled water. For example, if the ATPase reaction contained 1 mM ATP, at the end of reaction dilute reaction mixture 4-fold in water prior to the assay.
3. Add 20 μL of Working Reagent to each well. Mix gently by tapping the plate.
4. Incubate for 30 min at room temperature for color development.
5. Measure absorbance at 600 nm - 660nm (620 nm) on a plate reader.
For assays in 384-well plates, the procedures are the same, except that the volume of the standard and sample solution should be 40 μL and that of the Working Reagent should be 10 μL.
If precipitation occurs, perform a series dilution of sample in H2O, run the assay and determine the dilution factor from wells with no precipitation.
Repeat assays using diluted samples.
Enzyme reaction buffer. Because any exogenous free phosphate would interfere with the assay, it is important to ensure that the protein preparation, the reaction buffer and lab wares employed in the assay should not contain free phosphate. This can be conveniently checked by adding the Working Reagent to the buffer and measuring the color formation.

Liquid disposal. The assay mixture contains 0.4 M sulfuric acid. It is recommended that the waste liquid be neutralized with equal volume of 1 N NaOH prior to disposal.

DATA ANALYSIS
Plot OD620nm versus phosphate standard concentrations. Determine sample phosphate concentrations from the standard curve.

PUBLICATIONS
1. Guérette, D. et al (2007). Molecular evolution of type VI intermediate filament proteins. BMC Evolutionary Biology 2007, 7:164.
2. Green, M.L. et al (2005). Ethylene glycol induces hyperoxaluria without metabolic acidosis in rats. Am J Physiol Renal Physiol 289: F536–F543.
3. Saran, D. et al (2006). Multiple-turnover thio-ATP hydrolase and phospho-enzyme intermediate formation activities catalyzed by an RNA enzyme. Nucleic Acids Research, 34(11): 3201–3208.
4. Adkins, M.W. et al (2007). Chromatin disassembly from the PHO5 promoter Is essential for the recruitment of the general transcription machinery and coactivators. Mol. Cell. Biol. 27: 6372–6382.
 

TECHNICAL NOTES
The Malachite Green Phosphate Assay kits have been optimized and formulated to provide a sensitive, convenient and robust quantitation of free phosphate liberated from enzyme reactions and natural sources. Key features of the kits are as follows:


Reagent very stable. Due to our innovative formulation, no precipitation of reagent occurs. Therefore no filtration of reagent is needed prior to assays, as is often required with other commercial kits.

Safe. Non-radioactive assay.

High sensitivity and wide detection range: detection of as little of 1.6 pmoles of phosphate and 0.02 μM to 40 μM phosphate.

Fast and convenient: homogeneous “mix-and-measure” assay allows quantitation of free phosphate within 20 minutes.

 Compatible with routine laboratory and HTS formats: assays can beperformed in tubes or microplates, on spectrophotometers and plate readers.

Robust and amenable to HTS: Z’ factors of 0.7 to 0.9 are observed in 96-well and 384-well plates. Can be readily automated on HTS liquid handling systems.

Contact us about this product :

Our team will respond you as soon as possible !

Email :
Skype :
Name :
Phone :
address :
Question, Comment ... :
arrow security gentaurPlease retype this code below:
Bioassays \ Malachite_Green_Phosphate_Assay_Kit \ POMG_25H
Reload Image

 

GENTAUR Belgium BVBA BE0473327336
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45

Fax 0032 16 50 90 45
info@gentaur.com | Gentaur





GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
uk@gentaur.com | Gentaur

 

 




GENTAUR France SARL
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50

Fax 01 43 25 01 60
RCS Paris B 484 237 888

SIRET 48423788800017

BNP PARIBAS PARIS PL MAUBERT BIC BNPAFRPPPRG

france@gentaur.com | Gentaur

GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Support Karolina Elandt
Tel: 0035929830070
Fax: (+49) 241 56 00 47 88

Logistic :0241 40 08 90 86
Bankleitzahl 39050000
IBAN lautet DE8839050000107569353
Handelsregister Aachen HR B 16058
Umsatzsteuer-Identifikationsnummer *** DE 815175831
Steuernummer 201/5961/3925
de@gentaur.com | Gentaur

GENTAUR U.S.A
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
CA 95123
Tel (408) 780-0908,
Fax (408) 780-0908,
sales@genprice.com

Genprice Inc, Invoices and accounting
6017 Snell Ave, Ste 357
San Jose, CA 95123




GENTAUR Nederland BV
NL850396268B01 KVK nummer 52327027
Kuiper 1
5521 DG Eersel Nederland
Tel:  0208-080893  Fax: 0497-517897
nl@gentaur.com | Gentaur
IBAN: NL04 RABO 0156 9854 62   SWIFT RABONL2U






GENTAUR Spain
tel:0911876558
spain@gentaur.com | Gentaur






ГЕНТАУЪР БЪЛГАРИЯ
ID # 201 358 931 /BULSTAT
София 1000, ул. "Граф Игнатиев" 53 вх. В, ет. 2
Tel 0035924682280 Fax 0035924808322
e-mail: Sofia@gentaur.com | Gentaur
IBAN: BG11FINV91501014771636
BIC: FINVBGSF

GENTAUR Poland Sp. z o.o.


ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
TEL Gdansk 058 710 33 44 FAX  058 710 33 48              

poland@gentaur.com | Gentaur

Other countries

Österreich +43720880899

Canada Montreal +15149077481

Ceská republika Praha +420246019719

Danmark +4569918806

Finland Helsset +358942419041

Magyarország Budapest +3619980547

Ireland Dublin+35316526556

Luxembourg+35220880274

Norge Oslo+4721031366

Sverige Stockholm+46852503438

Schweiz Züri+41435006251

US New York+17185132983

GENTAUR Italy
SRL IVA IT03841300167
Piazza Giacomo Matteotti, 6
24122 Bergamo Tel 02 36 00 65 93
Fax 02 36 00 65 94
italia@gentaur.com | Gentaur