GENTAUR Molecular Products.
Monoclonal Antibody, ELISA Kit, Polyclonal Antibody, Recombinant/Purified Protein.GENTAUR Belgium BVBA BE0473327336
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45
GENTAUR U.S.A Genprice Inc 6017 Snell Ave, Ste 357, SanJose, CA 95123
Tel (408) 780-0908, Fax (408) 780-0908, sales@genprice.com
Index / Bioassays / SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t / Product Detail : SLLU-500 SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t
Related keywords:
Apr
20th
#SLLU-500 SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t
Price : | 314 | EUR |
357 | USD | |
244 | GBP | |
1321 | Zloty | |
42083 | JPY | |
2425 | NOK | |
2598 | SEK | |
355 | CHF |
Product name : SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t
Catalog number : SLLU-500
Quantity: 500tests
Availability: Yes
Supplier name : Bioassays
Data sheet: Ask more or other datasheet now !
About this Product :
SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t antibody storage GENTAUR recommends for long therm storage to freeze at -24 C. For short time storage up to 30 days we suggest fridge storage at 1 to 10 C. Prevent multiple freeze taw cycles of SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t.http://mybiofast.com/ver.php?search=anti-&submit=Search
More Details about
Bright bioluminescent reagent system for rapid quantitation of luciferase reporter gene expression in transfected cells and high-throughput drug screens.
Method: Lu.
Samples: cells etc.
Species: all.
Procedure: 2 min.
Size: 500 tests.
Detection limit: 2 fg luciferase.
DESCRIPTION
The SuperLightTM Luciferase Reporter Gene Assay is based on the
quantitation of luciferase expression in mammalian, yeast or E. coil cells,
using luciferin and ATP as substrates. The reaction results in light
production which can be conveniently measured on a luminometer.
Reaction scheme:
Luciferase
ATP + D-luciferin + O2 oxyluciferin + AMP + PPi + CO2 + light
This bioluminescent reporter gene assay is extremely sensitive and is
especially suitable for quantifying luciferase expression in recombinant
cells. This ultra-sensitive, homogeneous cell-based assay only requires
adding a single reagent to the cells and measuring the light intensity after a
short incubation step (2 minutes). Assays can be performed in tubes,
cuvettes or multi-well plates. All kit components are compatible with culture
media and with all liquid handling systems. With an extended luminescence
emission kinetics (half-life 40 min), the SuperLightTM luciferase assays are
especially suitable for high-throughput screening in 96-well, 384-well and
1536-well plates. In addition, the reagent provided in the kits has been
formulated for maximum sensitivity, reproducibility and long shelf-life.
Applications for this kit include gene regulation studies and high-throughput
screening of gene modulators.
KEY FEATURES
High sensitivity and wide detection range: detection of as little of 2 fg
luciferase and as few as 4 cells. Plus, the emitted light is linear over seven
orders of magnitude.
Compatible with routine laboratory and HTS formats: assays can be
performed in tubes or microplates, on LJL Analyst, Berthold Luminometer,
Top-Count, MicroBeta counters, chemiluminescent image plate readers
(CLIPR/LeadSeeker). Assay reagents compatible with all liquid handling
systems.
Fast and convenient: homogeneous “mix-and-measure” assay allows
detection of luciferase levels within 10 minutes. The optimally combined
reagent system allows a single addition step, and simultaneous cell lysis
and detection.
Robust and amenable to HTS: Z’ factors of 0.6 to 0.8 are observed in 96-
well and 384-well plates. Can be readily automated on HTS liquid handling
systems.
APPLICATIONS
Gene Regulation: gene expression level, characterization of promoter
activity, modulation of gene expression by receptors, transcription factors
and small molecules.
Drug Discovery: high-throughput screen for gene modulators.
KIT CONTENTS
Storage conditions. The kit is shipped at ambient temperature. Store the
Reagent in the provided amber tube at -20°C and the Assay Buffer at 2-8°C.
Shelf life: 12 months after receipt.
This protocol can be downloaded online at www.bioassaysys.com.
Precautions: reagents are for research use only. Normal precautions for
laboratory reagents should be exercised while using the reagents.
Contact us about this product :
Our team will respond you as soon as possible !
We have also other products like : SuperLight™ Luciferase Reporter Gene Assay Kit, Bright bioluminescent reagent system allows rapid quantitation of luciferase reporter gene expression in transfected cells within 2 min. Kit size 500 t
other names
GENTAUR Belgium BVBA BE0473327336
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45
Fax 0032 16 50 90 45
info@gentaur.com | Gentaur
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
uk@gentaur.com | Gentaur
GENTAUR France SARL
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50
Fax 01 43 25 01 60
RCS Paris B 484 237 888
SIRET 48423788800017
BNP PARIBAS PARIS PL MAUBERT BIC BNPAFRPPPRG
france@gentaur.com | Gentaur
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Support Karolina Elandt
Tel: 0035929830070
Fax: (+49) 241 56 00 47 88
Logistic :0241 40 08 90 86
Bankleitzahl 39050000
IBAN lautet DE8839050000107569353
Handelsregister Aachen HR B 16058
Umsatzsteuer-Identifikationsnummer *** DE 815175831
Steuernummer 201/5961/3925
de@gentaur.com | Gentaur
GENTAUR U.S.A
Genprice Inc, Logistics
547, Yurok Circle
San Jose, CA 95123
CA 95123
Tel (408) 780-0908,
Fax (408) 780-0908,
sales@genprice.com
Genprice Inc, Invoices and accounting
6017 Snell Ave, Ste 357
San Jose, CA 95123
GENTAUR Nederland BV
NL850396268B01 KVK nummer 52327027
Kuiper 1
5521 DG Eersel Nederland
Tel: 0208-080893 Fax: 0497-517897
nl@gentaur.com | Gentaur
IBAN: NL04 RABO 0156 9854 62 SWIFT RABONL2U
GENTAUR Spain
tel:0911876558
spain@gentaur.com | Gentaur
ГЕНТАУЪР БЪЛГАРИЯ
ID # 201 358 931 /BULSTAT
София 1000, ул. "Граф Игнатиев" 53 вх. В, ет. 2
Tel 0035924682280 Fax 0035924808322
e-mail: Sofia@gentaur.com | Gentaur
IBAN: BG11FINV91501014771636
BIC: FINVBGSF
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
TEL Gdansk 058 710 33 44 FAX 058 710 33 48
poland@gentaur.com | Gentaur
Other countries
Österreich +43720880899
Canada Montreal +15149077481
Ceská republika Praha +420246019719
Danmark +4569918806
Finland Helsset +358942419041
Magyarország Budapest +3619980547
Ireland Dublin+35316526556
Luxembourg+35220880274
Norge Oslo+4721031366
Sverige Stockholm+46852503438
Schweiz Züri+41435006251
US New York+17185132983
GENTAUR Italy
SRL IVA IT03841300167
Piazza Giacomo Matteotti, 6
24122 Bergamo
Tel 02 36 00 65 93
Fax 02 36 00 65 94
italia@gentaur.com | Gentaur
Gentaurpub
Pathways :
WP1963: The effect of Glucocorticoids on target gene expression
WP1031: IL-3 Signaling Pathway
WP1052: Id Signaling Pathway
WP1055: IL-4 signaling Pathway
WP1150: IL-3 Signaling Pathway
WP1168: Id Signaling Pathway
WP1171: IL-4 signaling Pathway
WP1263: Mitochondrial Gene Expression
WP1301: Mitochondrial Gene Expression
WP1359: IL-3 Signaling Pathway
WP1368: Mitochondrial Gene Expression
WP1374: Id Signaling Pathway
WP1376: IL-4 signaling Pathway
WP1449: Regulation of toll-like receptor signaling pathway
WP1545: miRNAs involved in DDR
WP182: IL-4 Signaling Pathway
WP1821: Gene Expression
WP2085: miRNAs involved in DDR
WP319: IL-3 Signaling Pathway
WP355: IL-1 Signaling Pathway
WP37: IL-1 Signaling Pathway
WP373: IL-3 Signaling Pathway
WP391: Mitochondrial Gene Expression
WP397: Id Signaling Pathway
WP512: Id Signaling Pathway
Related Genes :
Bibliography :
No related Items
Enter catalog number :
Favorites Pages:
No Favorits