GENTAUR Belgium BVBA BE0473327336 Voortstraat 49, 1910 Kampenhout BELGIUM Tel 0032 16 58 90 45
GENTAUR U.S.A Genprice Inc,Logistics 547 Yurok Circle, SanJose, CA 95123
Tel (408) 780-0908, Fax (408) 780-0908, [email protected]

Index / Cytognos / IgG1 Clone LF61 Description CD103 PE /Product Detail : CYT-103PE IgG1 Clone LF61 Description CD103 PE
Related keywords:

#CYT-103PE

IgG1 Clone LF61 Description CD103 PE

 Price: 636   EUR
722   USD
493   GBP

Product name : IgG1 Clone LF61 Description CD103 PE

Catalog number : CYT-103PE

Quantity: 1ml / 200 test

Availability: Yes

Supplier name : Cytognos

Data sheet Data sheet : Ask more or other datasheet now !

About this Product :

IgG1 Clone LF61 Description CD103_PE monclonal andibody monoclonal antobodies are directed against a specific epitope. The use IgG1 Clone LF61 Description CD103_PE is much more reproducable than with a polyclonal antibody.
monoclonal

More Details about

INTENDED USE
CD103-PE is a monoclonal antibody (MAb) labelled with R-phycoerythrin (PE) designed for flow cytometry use as a direct immunofluorescence reagent in the identification and enumeration of CD103 antigen-expressing cells.


SUMMARY AND EXPLANATION
Flow Cytometry (FC) is a powerful tool in analytical and quantitative characterization of cells which provides rapid and multiparametric analysis of heterogeneous cell populations on a cell-by-cell basis. Flow cytometry is performed on cell suspension after incubating it with fluorescent-labelled antibodies directed against specific cellular proteins. Positive cells relative fluorescence intensity indicates the amount of antibody bonded to specific cell sites providing information about antigen expression (1).
CD103 is normally expressed at very high levels on intra-epithelial lymphocytes in non-lymphoid tissues, such as skin, lung, and gastrointestinal organs that express E-cadherin. In contrast, CD103 is poorly expressed by T cells in blood, spleen, and lymph nodes (2).
Since its discovery, CD103 has been widely used for hairy cell leukaemia (HCL) diagnosis and despite rare exceptions CD103 has been detected together with CD25 in virtually all HCL studies using flow cytometry. CD103 is not ordinarily detected in other types of Blymphoproliferative disorders except for rare cases. CD103 can also be used to define a specialised subset of CD8+ cytolytic T
lymphocytes (3, 4).


PROCEDURE PRINCIPLES
Flow cytometry is an innovative technology that can evaluate simultaneously different characteristics for a single cell. Flow cytometers use hydrodynamic focusing to individually present cells to one or more laser beams. As cells are intercepted by light a set detectors recover signals of two different kinds: those generated by dispersed light (FSC/SSC), which mainly reflect cell size and internal complexity, and those related to fluorochromes light emission when cells are labelled. Recovered signals are then amplified by a series of linear and logarithmic amplifiers and converted in electrical signals large enough to be plotted graphically.
Fluorochrome-labelled monoclonal antibodies bind specific antigens, therefore cell populations carrying this antigen will be detected when the reagent is added to a sample and passed through a flow cytometer.
Detection of targeted populations can be hindered by erythrocytes presence. This problem can be avoided by their removal using a red blood cell lysing solution previous to sample acquisition. QuicklysisTM (CYT-QL-1) erythrocyte lysing solution without fixatives is recommended since it requires no washing steps. QuicklysisTM use minimises sample handling and avoids centrifuge processed which are usually associated to cell losses (5, 6).
CD103 positive cells are expressed as a percentage of total lymphocytes or leucocytes present in a sample. Since every flow cytometer has different operating characteristics each laboratory must determine its optimal operating procedure.


REAGENT COMPOSITION
The purified monoclonal CD103 antibody conjugated with R-phycoerythrin (PE) is supplied in phosphate-buffered saline (PBS) containing 0.1% sodium azide.
Clone: LF61.
Isotype: IgG1.
Amount per 1 ml vial: 100 tests (10 μl MAb per determination).
Reagent is considered non-sterile.


STORAGE CONDITIONS
The reagent is stable when stored at 2-8 ºC until expiration date shown on label. The reagent should not be frozen or exposed to direct light during storage or during cell incubation. Reagent vial should be kept dry and once open stored in vertical position to avoid any possible spillage.


WARNINGS AND RECOMMENDATIONS
1. For research use only.
2. This product is supplied ready to use, any modification by dilution or addition of other compounds should be validated by the user.
3. The reagent is stable until its expiry date when properly stored. Do not use it after expiration date shown on label. If product is stored in conditions different from those recommended, such conditions must be validated by the user.
4. Alteration in reagent appearance, such as precipitation or discoloration indicates instability or deterioration. In such cases, the reagent should not be used.
5. It contains 0,1% sodium azide (CAS-Nr. 26628-22-8) as a preservative but care should anyway be taken to avoid microbial contamination of reagent and reduce incorrect results that can probably arise from that contamination.
• Sodium azide (NaN3) is harmful if swallowed (R22). If swallowed, seek medical advice immediately and show this container or label (S46).
• Wear suitable protecting clothing (S36).
• Contact with acids liberates very toxic gas (R32).
• On disposal, flush with large amounts of water to prevent azide build-up in metal plumbing since explosive conditions may develop.
6. All patient specimens and materials are considered biohazards and should be handled as if capable of transmitting infection (7).
Disposal should be made according to the established legal precautions. It is also recommendable the use of appropriate protective gloves and clothing when handling this product. Product use should be made by personnel qualified to perform the described procedures. Avoid sample contact with skin or mucous membranes. Wash immediately with abundant water if skin contact has occurred.
7. Reagent use with incubation times or temperatures different from those recommended may cause erroneous results. Any changes in procedure must be validated by the user.

PROCEDURE
Material included
CD103-PE can be used for 100 determinations (10 μl MAb per determination).
Material required but not included
• 488 nm ion argon laser-equipped flow cytometer and appropriate computer hardware and software.
• Test tubes suitable for the used flow cytometer. Usually 6 mL tubes (12x 75 mm) with a rounded bottom are used.
• Automatic pipette (100μL) and tips.
• Micropipette and tips.
• Chronometer.
• Vortex Mixer.
• Isotypic control reagent.
• QuicklysisTM lysing solution.
• Wash buffer (phosphate buffered saline (PBS) containing 0.1% sodium azide).
Preparation
Whole blood sample must be taken aseptically by venipuncture (8, 9) in a sterilized tube containing an appropriate anticoagulant (use of
EDTA is recommended). Flow cytometry analysis require one hundred (100) μL whole blood sample per tube, assuming a normal range
of approximately 4 to 10 x 103 leucocytes per μL. Samples with high white blood cell count should be diluted with PBS to obtain an
approximate cell concentration of 1 x 104 cells/μL. Store blood samples at 18-22ºC until they are to be tested. It is advisable to test blood
samples within 24 hours after their extraction. Samples with suspended cell aggregates or haemolysed should be rejected.
1. Mix 100μL of peripheral blood with 10μL of CD103-PE. In case of working with other body fluids with fewer cells, such as
cerebrospinal fluid, bronchoalveolar lavage, gastric lavage, etc., start with an initial volume of 200 μL.
To evaluate non-specific binding of the antibody, an appropriated isotype control tube can be prepared.
2. Incubate in the dark at room temperature for 10 minutes.
3. Add 2 mL of QuicklysisTM* erythrocyte lysing solution and incubate sample in the dark at room temperature for 10 minutes.
4. Acquisition in the flow cytometer should be performed within the first four hours after sample preparation. If samples are not
acquired immediately after preparation, they should be stored in the dark at 2-8ºC. Instrument calibration must be done according to
manufacturers’ advice. Before acquiring samples, adjust threshold or discriminator to minimise debris and ensure that populations of
interest are included. Also, previous to acquisition samples should be mixed on a vortex (low speed) to reduce cell aggregation.
*Note: The use of other lysing solutions may require elimination of lysed red blood cells. Follow lysing solution manufacturer recommended protocol.
Flow cytometry analysis
Confirm that cytometer is correctly aligned and standardised for light dispersion and fluorescent intensity. Compensation should be set
following cytometer manufacturer instructions.
Evaluate CD103 against the appropriate lymphocyte marker (e.g. CD19 B-Cells, CD8 for Cytolytic T Cells).
Results are commonly reported as a percentage of sample total lymphocyte or leucocyte count present.


LIMITATIONS
• Blood samples should be stored at 18-22ºC and tested within 24 hours after they were obtained.
• It is advisable to acquire stained samples as soon as possible to optimise results. Non-viable cells may show unspecific staining.
Prolonged exposure of whole blood samples to lytic reagents may cause white cell destruction and targeted population cell loss.
• When using whole blood procedures some red blood cells may not lyse, for instance if there are nucleated red blood cells or if abnormal protein concentration and haemoglobinopathies are observed. This may cause misleading results since unlysed red blood cells are counted as leucocytes.
• Results obtained by flow cytometry may be erroneous if cytometer laser is misaligned or if gates are incorrectly set.
• Each laboratory should establish a normal range for CD103+ cells using its own test conditions.
• Certain patients may present special problems due to altered or very low number of a certain cellular population.
• Cells separated from whole blood by means of density gradients may not have the same relative concentration as in whole
blood. This may be relatively insignificant in individuals with normal white blood cell counts. In leucopenic patients, the selective loss of specific subsets may affect determination accuracy.
• Knowledge of antigen expression pattern and its relation to other antigens is paramount to carry out an adequate analysis (10, 11).
• Abnormal states of health are not always represented by abnormal percentages of certain leucocyte populations. An individual in an abnormal state of health may show the same leucocyte percentage as a healthy person.


EXPECTED VALUES
CD103 is found on 90% of intraepithelial lymphocytes, on 40% of mucosa-associated T cells and only on 0.5–3% of peripheral blood lymphocytes. CD103 is identified in virtually all HCL diagnosis cases (11). This information is based on the consulted bibliography and has mere informative character.


QUALITY CONTROL
• Pipettes precision and cytometer calibration should be verified to obtain optimal results.
• In multicolour panels, fluorochromes emit in wavelengths that can show certain spectral overlap which must be corrected by electronic compensation. Optimal compensation levels can be established by analysing cells from healthy individuals stained with mutually exclusive monoclonal antibodies conjugated with appropriate fluorochromes.
• Non-specific binding of the antibody can be evaluated using an appropriated isotype control tube.

Contact us about this product :

Our team will respond you as soon as possible !

Email:
Name:
Phone:
Question, Comment :